Analysis of the factors determining the error of fl ow with constricting devices on channels of head pumping stations
https://doi.org/10.26897/1997-6011-2023-2-99-105
Abstract
In the conditions of increasing scarcity of water resources, the problem of their economy and rational use is of paramount importance. The restructuring of the existing water metering system should be carried out in a comprehensive and step-by-step manner. When accounting for water, the greatest diffi culty is the problem of measuring water flow. The paper summarizes and presents the methods of error estimation that allow us to objectively assess the compliance of flow meters with technical conditions at the stages of manufacture, installation and operation. The effciency of water metering is largely determined by the level of operation of measuring instruments. In this regard, the unifi cation of the process of collecting, processing and presenting information should play an important role. The purpose of the research is to substantiate a mathematical model of the error of flow meters with tapering devices by analogy with the methods regulated in the current regulatory documents.
About the Authors
M. S. АliRussian Federation
Аli Munzer Suleiman, candidate of technical sciences, associate professor
127434, Moscow, Timiryazevskaya, 49
WoS ResearcherID: AAE-5905-2022
Scopus AuthorID: 57183440800
AuthorID: 709443
D. S. Beglyarov
Russian Federation
Beglyarov David Surenovich, doctor of technical sciences, professor
127434, Moscow, Timiryazevskaya, 49
A. A. Naumova
Russian Federation
Naumova Anna Anatolyevna, senior lecturer
127434, Moscow, Timiryazevskaya, 49
AuthorID: 1010469
E. E. Nazarkin
Russian Federation
Nazarkin Eduard Evgenievich, senior lecturer
127434, Moscow, Timiryazevskaya, 49
WoS ResearcherID: AAE-5123-2022
Scopus AuthorID: 57224938329
AuthorID: 939300
References
1. Kireycheva L.V., Yurchenko I.F., Yashin V.M. Scientifi c foundations for the creation and management of reclamation systems in Russia: monograph / Under the scientifi c editorship of Kireycheva L.V. M.: FSBNU «VNII agrochemistry», 2017. S. 296.
2. Pakhomov A.A. Device for measuring water flow in open channels / A.A. Pakhomov, SV. Tronev K.M. Melikhov, N.A. Kolobanova // Melioration and water management, M., 2009, No. 4 P. 29-33.
3. Ali М.S., Beglyarov D.S., Chebaevsky V.F. Pumps and pumping stations: a textbook. M.: Publishing House of RGAU-MSHA, 2015. S. 330.
4. Kharchenko S.I. Hydrology of irrigated lands. 2nd ed., reprint. and add. L.: Hydrometeoizdat, 1975. S. 371.
5. Beglyarov D.S., Agarkov I.P., Rybkin V.N. Means of measuring fl ow and pressure on irrigation networks of reclamation systems: Textbook: Moscow Hydromelioration Institute. M.: MGMI, 1995. S. 79.
6. Altschul A.D. Hydraulic resistances of pipelines. 2nd ed., reprint. and add. M. Nedra, 1982. – S. 224.
7. Hydraulic structures. Designer’s Handbook. – M.: Stroyizdat, 1983. S. 543.
8. Kremlevsky P.P. Flowmeters and counters of the amo unt of substances: a reference book. In 2 books. 5th ed., re vis ed. and additional. St. Petersburg: Polytechnic, 2002.
9. Yemtsev B.T. Technical hydromechanics: textbook. textbook for universities. M.: Mechanical Engineering, 1987. S. 440.
10. Sterenlicht D.V. Hydraulics: a textbook for universities. – 3rd ed., Rev. And additional.M.: Kolos, 2004. S. 656.
11. Valentini K.A., Lobachev P.V. Estimation of the error of the fl ow coeffi cient of some narrowing devices as a result of their deviation from the standard form. / Digest: Measuring equipment of water management systems. Proceedings of VNII VODGEO. M.: 1983
12. 12. OST-33-27-80. Flow meters for water reclamation systems. General specifi cations. URL: https://www.standards.ru/print.aspx?control=27&id=3600214&print=yes.
13. GOST R ISO 5725-6-2002. Accuracy (correctness and precision) of measurement methods and results. Using precision values in practice. Introduced 2002-04-23.M.: Publishing house of Standards, 2002. S. 43.
Review
For citations:
Аli M.S., Beglyarov D.S., Naumova A.A., Nazarkin E.E. Analysis of the factors determining the error of fl ow with constricting devices on channels of head pumping stations. Prirodoobustrojstvo. 2023;(2):99-105. (In Russ.) https://doi.org/10.26897/1997-6011-2023-2-99-105