Abstract

In cases where the supply of energy sources to hydraulic structures located on irrigation canals is economically unjustified, hydraulic automation means are widely used in Russia and abroad. The purpose of the research is to derive design dependencies to determine the flow rate of the injected and injected flows, taking into account hydraulic losses within the flow path of the structure, to construct the flow characteristic of the regulator with a nozzle and an output section of a constant area with its subsequent verification by the data of the hydraulic experiment. Injection flow regulators have several modifications: with a diffuser outlet section without restricting the outlet pipe with a nozzle, with a nozzle and diffuser, with a nozzle and an outlet section of a constant area. For regulators with a nozzle, dependences for hydraulic calculations have now been obtained, which can be considered conditionally “ideal”, since they do not take into account a number of local resistances and frictional resistances along the length that arise when flows merge with subsequent movement in the mixing chamber. As a result of the research, the authors for the first time obtained calculated dependencies for determining the flow rate of the injected and injected flows, taking into account hydraulic losses within the flow path of the structure, and constructed the flow characteristic of a regulator with a nozzle and an outlet section of a constant area. The flow characteristic is verified using available hydraulic experiment data. An analysis of the shape of the flow characteristics of the injection regulator was carried out by comparison with the generalized characteristics of hydraulic jet pumps. The practical significance of the research lies in the possibility of using the dimensionless characteristics of the injection water outlet to link it to specific operating conditions, as is customary when selecting pumps. To determine the flow rates in the regulator, a computer program has been registered.

About the Authors

V. L. Snezhko
National Research Moscow State University of Civil Engineering
Russian Federation

Snezhko Vera Leonidovna, doctor of technical sciences, professor; Scopus Author ID: 57209333075; ВЕБ ABG‑5645‑2020; РИНЦ AuthorID: 696880

26, Yaroslavskoye Shosse, Moscow, 129337



D. D. Kobozev
Russian State Agrarian University Moscow State Agricultural Academy named after C.A. Timiryazev
Russian Federation

Daniil Dmitrievich Kobozev, post graduate student, AuthorID: 1083396

127434, Timiryazevskaya str., 49



References

1. Kadirova.G. Hydraulic automatic regulator of level with fl exible working bodies, E3S Web Conf. 264, 03039 (2021). DOI: 10.1051/e3sconf/202126403039

2. Pakhomov A.A., Kolobanova N.A. Automated control of the water supply process using hydraulic control devices // Scientifi c journal of the Russian research institute for land reclamation problems. 2013. № 4 (12). P. 168-178.

3. Gaisin A.A. A method for improving hydrodynamic flow regulators // Scientific journal of the Russian research institute for land reclamation problems, 2015, No. 3(19), P. 159-170.

4. Kobozev D.D., Snezhko V.L. Comparison of the hydraulic characteristics of injection regulators with different designs of the outlet section // Hydrotechnical Construction. 2023. No. 2. P. 29-33.

5. Tubular water outlet-regulator. Patent for a utility model. 219538 U1, 07/21/2023. / Petrashkevich V.V., Benin D.M., Mikheev P.A., Tkachev A.A., Petrashkevich A.V. Application No. 2023107239 dated 03/27/2023.

6. Sokolov E.Ya., Zinger N.M. Jet devices. 3rd ed., revised.M.: Energoatomizdat, 1989. 352 p.

7. Aldas K. and Yapici R. Investigation of Effects of Scale and Surface Roughness on Efficiency of Water Jet Pumps Using CFD // Engineering Applications of Computational Fluid Mechanics. 2014. 1: Vol. 8.pp. 14-25.

8. Benin D.M., Kobozev D.D., Snezhko V.L. Injection flow regulators without diffuser outlet sections // Prirodoobustrojstvo. 2022. No. 1. P. 47-53. DOI: 10.26897/1997-6011-2022-1-47-53.

9. Reddy Y.R. & Kar S., Theory and performance of water jet pump, Trans. ASCEJ. Hyd. Div., 94-5 (1968), 1261-1281.

10. Lomakin V.O., Chaburko P.S. The influence of the geometric shape of a jet pump nozzle on its characteristics // Science and Education. MSTU named after N.E. Bauman. Electronic journal. 2014. No. 12. P. 128-136. DOI: 10.7463/0815.9328000

11. Podvidz L.G., Kirillovsky Yu.L. Calculation of jet pumps and installations // Proceedings of VNIIGidromash. 1968. Issue XXXVIII. P. 44-96.

12. Kobozev D.D. Program for calculating the depth of a diffuserless injection flow regulator. Certificate of registration of the computer program 2023668252, 08/24/2023. Application No. 2023666993 dated 08/15/2023.

13. Lyamaev B.F. Hydrojet pumps and installations.L.: Mechanical engineering. Leningrad branch, 1988. 256 p.

14. 14. Long X., Han N. and Chen Q. Influence of nozzle exit tip thickness on the performance and flow field of jet pump. Journal of Mechanical Science and Technology. 2008. 22. P. 1959-1965.